Details

ManufacturerGuangdong Chant Group Inc
Product Number085-1522-0
Model PG601
Rated Heat Output40,000 BTU
GasPropane
Max/Min PSI150/5


Pictures



Removing the Heater Assembly 



Heater Assembly (Not exact)

The above burner has a separate gas line which runs to the thermocouple and main burner which would work better then what I have.



Thermocouple

https://www.amazon.ca/Aupoko-Thermocouple-Replacement-Connection-Terminal/dp/B07MCLD6TX/ref=sr_1_7?crid=1TLY7PVX82MXT&dchild=1&keywords=patio+heater+thermocouple&qid=1624977896&sprefix=patio+heater+thermo%2Caps%2C167&sr=8-7

Should Flames Touch Thermocouples?

Yes, the pilot flame touches thermocouples at a certain level. If flames are weak and blue they hardly reach thermocouples, therefore, they should be strengthened. If flames extend past thermocouples, they are stronger. The perfect position is when flames cover the tops of thermocouples and burn with yellow-tips.




How Do You Test Patio Heater Thermocouples?

What you’ll need for the test :

The open-circuit test is quite a straightforward process, but it is best to look for a professional if you lack experience.

Issues

IssueSolution

Flame turns of after a while on high

  • clean thermocouple
  • re-align thermocouple
  • clean any debris from gas line
  • replace thermocouple and tilt/dump switch 


Fix

Since my burner doesn't have a separate pilot light gas line like the above, it is crucial that the thermocouple is positioned just right! We want to the thermocouple to be in an area far enough from the burner to still get flame when on high. 


The fix here was to move the themocouple bracket closer to the burner and angle it up at a bit of an angle.

References

ReferenceURL
What Is A Patio Heater Thermocouple? Troubleshooting Guide.https://patioheaterexpert.com/thermocouple-troubleshooting/
https://www.youtube.com/watch?v=y6lXa3X28P4