These settings can be applied to both solar charge controllers and chargers.
The typical charge settings for a sealed lead acid battery would be fine but if you want to get them optimaized, they should be as follows:
Setting | Value |
---|---|
Temp Coeff | 0 mv/C/2v |
Charge Limit | 14.6v |
Float Charge | 13.6v |
Equalize Time | 0 minutes |
References
Reference | URL |
---|---|