SIN9020S Voltage Meter

Overview

The SIN9020S voltage meter is able to measure:

  • voltage
  • current
  • charge and discharge capacity
  • time
  • power

Protection Features

  • over voltage protection
  • under voltage protection
  • over current protection
  • over-charging capacity protection 


Technical Specs

Project

Parameters

Voltage measuring range

Self-powered voltage measurement  range

10V~90V

External power measurement range

0~90V

 Current input \ output current measurement range

          0~20A

Display method

  Color liquid crystal display

Display Resolution

Voltage

0.01V

Current

0.01A

Capacity

0.01AH

Time

1min

Accuracy

Voltage

 1% + 2 words

Current

 2% + 5 words

             Measurement rate

 5 times / sec


OFT (out protection)

0.01H~99.9H

Dimensions (length × width × height)

79×43×52(mm)

Mounting hole opening (mm)

76.5*39.2(mm)

Wiring

From factory, Vext is connected to VCC. 


To power the meter from an independent source, you will need to unsolder a jumper inside the meter. Once done, you can power the meter from an independent source.


Settings

Protection Functions

  • OVP - Over Voltage Protection

  • OPP - Over Power Protection
  • OCP - Over Current Protection
  • OFT - Over Time Protection
  • OAH - Over Ah Protection
  • LOP - Under Voltage Protection - Does not work with this model since there is no relay

To Enable Protection Functions

  • navigate to it using the up and down arrows
  • click the OK button.

The indicator will turn green when enabled and grey when disabled.

To Set Protection Function Parameters

  • navigate to it using the up and down arrows
  • click and hold the OK button for about 3 seconds
  • adjust the value by using the arrow keys
  • press OK to exit

Factory defaults are 000.

Setting the Capacity of your Battery

  • navigate to OAH using the up and down arrows
  • click and hold the OK button for about 3 seconds
  • set the Ah capacity by using the arrow keys
  • press OK to exit

Charge/Discharge Indicator

The OUT arrow will point:

  • Right for Charging
  • Left for discharging

Resetting Meter

To reset the meter, move the arrow below LOP and click OK.

Calibration Mode

Power off the meter, click and hold the ok button and power up the meter.

Turn Screen off

Move arrow up past VOP and click OK.

VAC9010H Meter

This model is similar to the SIN9020S meter but has a current transformer for measuring current. This model also has the ability to trigger a relay in the event of low voltage.


Wiring

Connections

All connections to the meter are made from the current capacitor board.


ConnectionDescription
Bat

Batter Monitoring Connection (10-90v)

Meter will get power from this connection when jumper is set to J4.

Relay +/-Relay Connection 
Vext +/-Power supply connection. When connecting a relay, this voltage will be used to trigger the relay. (10-60v)
Jumper 

J3 - Relay or Power Supply Connections

J4 - No Relay or Power Supply Connections


With No Relay or Power Supply Connections

Note: Jumper should be set to J4.

With Independent Meter Power

Note: Jumper should be set to J3.

With Relay

Note: Jumper should be set to J3.



References

ReferenceURL
Manual for SIN9020S Meter
Manual for VAC9010H Meter