Model: Back-UPS ES 750

Battery Details

SpecificationDetail
Image

PartAJC-D7S
Voltage12v
Capacity7Ah
Type

Sealed Lead Acid (AGM)

TerminalsF2
Length5.94 in / 150.9 mm
Width2.56 in / 65 mm
Height3.7 in / 94 mm
Weight4.5 lbs


Lithium Iron Phosphate Battery Replacement


I ordered this LiFePO4 battery off amazon which is the exact same size as the original.

...

I performed a capacity test on the old lead acid battery. The battery had a 3 Ah capacity when drained to 10.5v at 2A.


Shutdown Problem

I ended up having some quick shutdowns after replacing the battery.  

...

Testing the battery with a 10A load, the battery quickly dropped to 11.6V which the UPS would consider to be 0% left!


Configuring the UPS

List Commands

Code Block
> upscmd -l  ups@localhost

Instant commands supported on UPS [ups]:

beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
test.panel.start - Start testing the UPS panel
test.panel.stop - Stop a UPS panel test

...

Code Block
>upscmd ups@localhost test.battery.start.quick

>upscmd ups@localhost ups.test.result