Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Turn off pool timers - pool.jmehan.com
  • Set heater to off.
  • Turn power off.
  • Turn off gas using external shutoff.
  • Drop water level below returns by about an inch or so using sump pump (about 5 hours).
  • Remove return jets

...

  • Depressurize system by releasing air from top of filter.
  • Remove pump drain plug and disconnect pump.
  • Attach zip lock bag over wires and secure with an elastic.
  • Drain cartridge filter and remove pleated filters.
  • Force air though filter output through heater.
  • Remove drain plug from heater.
  • Remove salt cell and install winter cap.
  • Clean filter parts and put in filter and re-seal.
  • Plug pump output and force air through filter drain. This will force air through the return lines.

Image AddedImage Added

  • Force air through returns lines  using a shop vac. Plug one return using plugs to force water out other line and then repeat with the other line.
  • Remove drain plug from heater and force out water with air.
  • Force air through intake(skimmer) line and attach "gizmo". Vacuum skimmer if needed.vacuum out remaining water.

Image Added


  • Add antifreeze to return lines and plug.
  • Add antifreeze to skimmer intake line.
  • Open top of heater and turn gas off
  • drain and attach "gizmo"
  • Plug Pump Input.
  • Remove salt cell and install winter cap.Turn off gas using external shutoff
  • Clean filters.
  • Store pump, salt cell inside. Store filters inside garage attic.
  • Install Cover


Water Chemistry

Important

Info
titleAlways
  • Turn off cell for 24 hours after adding salt
  • Wait 48 hours after shock before getting sample for water test

...

After a couple of weeks, notice the Ph was high.

ReadingValueStatusDesired StateCalculated Chemicals NeededWhat I AddedResult (Next Morning)
Ph8.0OK7.4-7.6480g Ph-300g Ph-