Voltage/Capacity when performing discharge test on Oct 27th:

VoltageCapacityCapacity based on VoltageMultiplierEstimated Capacity
12.65250090% (10% used)x1025 Ah
12.594200


12.50830080% (20% used)x541.5 Ah


Voltage/Capacity when performing discharge test on Nov 1st:

VoltageCapacityCapacity based on VoltageMultiplierEstimated Capacity
12.241796460% (40% used)x2.572 Ah



Test Results after addition of distilled water:

TestFinal VoltageCapacity (mAh)% of Capacity
Oct 27, 201910.1613.,39217%
Nov 1, 2019



Appendix

Disabling Safety Timer and Capacity Cut Off on IMAX B6

...