Voltage/Capacity when performing discharge test on Oct 27th:
Voltage | Capacity | Capacity based on Voltage | Multiplier | Estimated Capacity |
---|---|---|---|---|
12.65 | 2500 | 90% (10% used) | x10 | 25 Ah |
12.59 | 4200 | |||
12.50 | 8300 | 80% (20% used) | x5 | 41.5 Ah |
Voltage/Capacity when performing discharge test on Nov 1st:
Voltage | Capacity | Capacity based on Voltage | Multiplier | Estimated Capacity |
---|---|---|---|---|
12.24 | 17964 | 60% (40% used) | x2.5 | 72 Ah |
Test Results after addition of distilled water:
Test | Final Voltage | Capacity (mAh) | % of Capacity |
---|---|---|---|
Oct 27, 2019 | 10.16 | 13.,392 | 17% |
Nov 1, 2019 |
Appendix
Disabling Safety Timer and Capacity Cut Off on IMAX B6
...