TestCapacity (mAh)% of Capacity
Initial Test6579 mAh8%



Next Steps

We will check discovered that the water levels in this battery and if they are low, we will top up with distilled water.Ok, so the water levels were very low. Added distilled water about 1/4" above the plates. 

(It's hard to visually see the water level. Perhaps we could use a stick or something next time to check the level.

While Testing:

@12.65V = 2498 mAh

Calculating based on 12.65 being about 90% capacity, then we would expect about 25Ah. Not quite the 80Ah it is supposed to have... wait and see.

Voltage/Capacity when performing discharge test on Oct 27th:

...

.

...

)

...

...


Voltage/Capacity when performing discharge test on Nov 1st:

...

Test Results after addition of distilled water:

TestFinal VoltageCapacity (mAh)% of CapacityChanges
Oct 27, 201910.1613,39217%Added distilled water
Nov 1, 20198.6922,22628%Added more distilled water
Nov 7, 201910.024,54331%Shook
Nov 12, 201910.527,29134%Shook
Nov 18, 201910.529,31537%Shook



Appendix

Disabling Safety Timer and Capacity Cut Off on IMAX B6

...