Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Battery

The battery being tested is a Nautilus Marine/RV battery.

...

SpecificationValue
MakeMotomaster Nautilus
Model010-2799-4
Capacity80Ah
Group27


Discharge Test

A discharge test was performed using the SkyRC Max B6 charger. In order to get the test to run to completion, we had to disable the Capacity Cut off  and the Safety Timer (See appendix). 

...

TestCapacity (mAh)% of Capacity
Initial Test6579 mAh8%



Next Steps

We discovered that the water levels in this battery were very low. Added distilled water about 1/4" above the plates. 

...

TestFinal VoltageCapacity (mAh)% of CapacityChanges
Oct 27, 201910.1613,39217%Added distilled water
Nov 1, 20198.6922,22628%Added more distilled water
Nov 7, 201910.024,54331%Shook
Nov 12, 201910.527,29134%Shook
Nov 18, 201910.529,31537%Shook



Appendix

Disabling Safety Timer and Capacity Cut Off on IMAX B6

In order to get the test to run to completion, we had to disable the Capacity Cut off  and the Safety Timer.


Reference

...