SpecificationValue
MakeMotomaster Nautilus
Model010-2799-4
Capacity80Ah(20h)
Group27


Charging Our Battery

...

Charging ParametersValue
Battery TypeSLA (includes Flooded)
SpeedFast (4A)
Max Voltage14.4v
Current4A


Charging StepsImage Removed



Image Added


Permanent capacity loss can be minimized with operating at a moderate room temperature and a float voltage of 2.25–2.30V/cell (13.5-13.8V).

Discharge Test


A discharge test was performed using the SkyRC Max B6 charger. In order to get the test to run to completion, we had to disable the Capacity Cut off  and the Safety Timer (See appendix). 

...

TestFinal VoltageCapacity (mAh)% of Capacity

Capacity if 10.8v is 80%

Capacity/64000*100
Changes
Oct 27, 201910.1613,39217%-Added distilled water
Nov 1, 20198.6922,22628%-Added more distilled water
Nov 7, 201910.024,54331%-Shook
Nov 12, 201910.527,29134%43%Shook
Nov 18, 201910.529,31537%46%Shook
Nov 24, 201910.530,84739%48%Shook
Nov 30, 201910.632,41341%51%Shook


Questions

  • Does a lead acid battery rated at 80Ah actually give you 80Ah??

This battery is rated to deliver at 80Ah over a period of 20h which translates to 4A/hour for 20 hours until it reaches 10.5v.


Conclusions

We managed to get our battery back up to a reasonable value about 40% of it's rated capacity and in the process discovered:

...