Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To power the meter from an independent source, you will need to unsolder a jumper inside the meter. Once done, you can power the meter from an independent source.


Useful Functionality

How to Set Functions

...

Settings

Protection Functions

  • OVP - Over Voltage Protection

  • OPP - Over Power Protection
  • OCP - Over Current Protection
  • OFT - Over Time Protection
  • OAH - Over Ah Protection
  • LOP - Under Voltage Protection - Does not work with this model since there is no relay

To Enable Protection Functions

  • navigate to it using the up and down arrows

...

  • click the OK button.

The indicator will turn green when enabled and grey when disabled.

To

...

Set Protection Function Parameters

  • navigate to it using the up and down arrows
  • click and hold the OK button for

...

  • about 3 seconds
  • adjust the value by using the arrow keys

...

  • press OK to exit

. Factory defaults are 000.

VOP - Over Voltage Protection

OPP - Over Power Protection

OCP - Over Current Protection

OFT - Over Time Protection

OAH - Over Capacity Protection

LOP - Under Voltage Protection 

LOP is under voltage protection. When the output voltage drops below the setting, the meter will automatically cut off the output, and the output indicator will change from green to gray.

...

Setting the Capacity of your Battery

  • navigate to OAH using the up and down arrows
  • click and hold the OK button for about 3 seconds
  • set the Ah capacity by using the arrow keys
  • press OK to exit

Charge/Discharge Indicator

The OUT arrow will point:

  • Right for Charging
  • Left for discharging

Resetting Meter

To reset the meter, move the arrow below LOP and click OK.

Calibration Mode

Power off the meter, click and hold the ok button and power up the meter.

Turn Screen off

Move arrow up past VOP and click OK.

VAC9010H Meter

...

All connections to the meter are made from the current capacitor board.


ConnectionDescription
Bat

Batter Monitoring Connection (10-90v)

Meter will get power from this connection when jumper is set to J4.

Relay +/-Relay Connection 
Vext +/-Power supply connection. When connecting a relay, this voltage will be used to trigger the relay. (10-60v)
Jumper 

J3 - Relay or Power Supply Connections

J4 - No Relay or Power Supply Connections


With No Relay or Power Supply Connections

...