Someone else's solution
Capacity Tests
First Discharge Test
Battery Pack | Configuration | Expected Capacity | Starting Voltage | Final Voltage | Capacity (mAh) | % Capacity | Thoughts |
---|---|---|---|---|---|---|---|
1 | 4S8P | 16Ah | 12.94v (3.235v/cell) | 8v (2.0v/cell) | 3163 | 20% | Must be dead cells |
2 | 4S8P | 16Ah | 13v (3.5v/cell) | 8v (2.0v/cell) | 3234 | 20% | |
3 | 4S8P | 16Ah | 13v (3.25v/cell) | 8v (2.0v/cell)?? | 3358 | 21% |
Thoughts:
Perhaps these batteries were not fully charged. Need to charge and re-test.
References
Reference | URL |
---|---|
Buying Used Batteries | https://batteryhookup.com/ |
A123 Spec | https://www.batteryspace.com/a123-lifepo4-26650-rechargeable-cell-3-3v-2500-mah-50a-rate-8-25wh-anr26650m1b---un38-3-passed-and-iec-listed.aspx |
Battery Pack Calculator | http://repackr.com/ |
LiFePower LiFePO4 Batteries | https://www.sawtechnology.com/solarengine-battery |
...