Model: Jandy JXi Gas-Fired Pool and Spa Heater 260N


Wiring Connections

Image Added

Pool/Off/Spa Connector

Connecting to a Remote Pool-Off-Spa Selector (3-Wire Connection) (See b above)

  • Turn off the power to both the pool/spa control system and the heater unit.
  • Follow service access instructions from Section 6.1.
  • Run the wires from the pool/spa control system through the low voltage knockout on the right or left hand side of the heater.
  • Connect the wiring from the pool/spa control system to the heater remote control terminal. See Figure 16 item “b”.
  • Connect the three wires to the Spa, Pool & Common terminals of the J6 terminal bar.
  • Reinstall front panel.
  • Restore power to the heater and the pool/spa control system.

NOTE: When a fireman’s switch is being utilized and “hi-lo-com” is selected, the heater will fire automatically when the contacts close even if the user interface on the heater is off.


Configure the Control Panel

  • Make sure the pool heater is OFF.
  • Press and hold MENU, then the POOL and SPA buttons for 5 seconds to access Service Setup mode.

NOTE: The display will revert back to OFF 1 minute after the last key press.

  • Press Up or Down to display REMOTE.
  • Press MENU, REMOTE OFF (default) is displayed.
  • Use Up or Down to scroll through the Remote options until HI-LO-COM is displayed, then press MENU to select.
  • Press POOL or SPA to exit Service Setup mode



RS-4865 Interface


RS485 protocol, wiring & adapters

...