Leak Repair (Diverter Valve)
Problem
I noticed that the hot tub temperature was low (80F) so I went to check on it. I then discovered that the water level was below half way. The pump was still trying to move the water around.
Checking the outside of the hot tub revealed the leak was on the same said as the main diverter valve. The main diverter valve had a small leak in the past but I let it go since it seemed to be leaking into the hot tub and only when on high. It seems that it found a way to make things more exciting for me.
Removing the side panel revealed the water but no noticeable leaks so I assumed it must be the leaking diverter valve.
An inspection of the electrical revealed that the fuses for the heater had blown.
Fix
Doing a valve replacement for this particular valve would be tricky since it is