Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

I attempted to see if I could bypass the high temperature cut off but had no luck. Here are some pictures of the circuit board.



Temporary Fix

Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.

Image Added


Fix

I managed to buy a similar hot water tank with the same controller. Transfered the new controller to the old tank and all was well again. Perhaps I should have just installed the newer tank but didn't want to mess with all of the plumbing and the gas. Might do it at some point since the other tank is newer.

Temporary Fix

Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.

Image Removed

Donor Tank

SpecificationDetails
MakeGiant
ModelUG50-40LFPV1-N2U-DE
Capacity50 US Gal
Recup per/hour37.3 US Gal
User Manual



Ignitor Problem


Temporary Fix

Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.

Image Added



References

ReferenceURL
SuperFlue Hot Water Tank Manual
Intellivent Trouble Shooting Guide
Service Manual

...