I attempted to see if I could bypass the high temperature cut off but had no luck. Here are some pictures of the circuit board.
Temporary Fix
Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.
Fix
I managed to buy a similar hot water tank with the same controller. Transfered the new controller to the old tank and all was well again. Perhaps I should have just installed the newer tank but didn't want to mess with all of the plumbing and the gas. Might do it at some point since the other tank is newer.
Temporary Fix
Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.
Donor Tank
Specification | Details |
---|---|
Make | Giant |
Model | UG50-40LFPV1-N2U-DE |
Capacity | 50 US Gal |
Recup per/hour | 37.3 US Gal |
User Manual |
Ignitor Problem
Temporary Fix
Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.
References
Reference | URL |
---|---|
SuperFlue Hot Water Tank Manual | |
Intellivent Trouble Shooting Guide | |
Service Manual |
...