EquipmentSeriesMakeModelSN#Details
HeaterJandy Pro SeriesJandy JXi Gas-Fired Pool and Spa Heater260NLT EC02 0501 1919 0071


Quick Reference Guide:

h0454800.pdf


Seems to heat pool at 2-3 ºF/Hour

Chlorine GeneratorJandy Pro SeriesJandy TrueClear

https://www.jandy.com/-/media/zodiac/global/downloads/h/h0613500.pdf
PumpJandy Pro SeriesFloproFHPM.75CNDD16JA 2203
Filter

Jandy Pro Series

CV Series Filters

CV340

Cartridge filter

340 sqft filter capacity

Manual: H0291800.PDF


Parts

Plumbing Parts

...

O-Rings for Couplers

Inside Diameter: 66mm ~2.6" (2 19/32" )

Outside Diameter: 72.6mm ~2 7/8"

Width/Thickness: 3.4mm ~ 0.13" (17/128" ~ 1/8")

Part: 

????      R0446400 JANDY | UNION O-RING, SET OF 2

Pump

https://www.poolsuppliescanada.ca/jandy-flopro-fhpm-pump-parts

...

PartDetails
23 O-rings 
R0358000 O-Ring Replacement Kit for Zodiac Jandy DE DEL DEV CL CV Series Cartridge Pool Filter, Compatible with Models CV340 CV460 CV580 CL340 CL460 CL580 DEV48 DEV60 DEL48 DEL60

https://www.amazon.ca/R0358000-Replacement-Zodiac-Cartridge-Compatible/dp/B09SH2PVRD/ref=sr_1_9?keywords=jandy+filter+o+ring&qid=1684335866&sprefix=jandy+filter+o-%2Caps%2C111&sr=8-9

https://www.poolsuppliescanada.ca/zodiac-r0358000-o-ring-replacement-kit.html


Liner


Automation/Timers

Pump Timer

...

  • remove plugs from returns and skimmer
  • install return diverters and aim downward towards each other when using barracuda.
  • install return diverters and aim clockwise


  • run water into pump to fill up intake line.
  • turn pump on


  • install pool thermometer (ink-bird)




  • test pool water and submit to pool company for analysis
    •  add chemicals as needed

Closing the Pool

Buy

  • Winterizing Chemicals
  • Gizzmo
  • Antifreeze
  • Cell cleaner

...

  • Depressurize system by releasing air from top of filter.
  • Remove pump drain plug and disconnect pump.
  • Drain cartridge filter and remove pleated filters.
  • Force air though filter output through heater.
  • Remove drain plug from heater.
  • Disconnect and remove Remove salt cell and install winter cap.


  • Force air through returns lines  using a shop vac. Plug one return using plugs to force water out other line and then repeat with the other line.
  • Force air through intake(skimmer) line and attach "gizmo". Vacuum skimmer if needed.

...

ReadingValueStatusDesired StateCalculated Chemicals NeededWhat I AddedResult (Next Morning)
Hardness252Ideal200-300--
Chlorine2.56

--
Alkalinity78Low80-120 

 1kg of Alka+

1kg Alka+
Ph7.8High7.4-7.6210 g PH-210g PH-
Stabilizer3Low30-60600g Stabilizer3 stab ultra pucks to skimmer
Salt2349Low300022 kg Salt (1 bag = 20kg)20kg - 1 bag salt



Water Report - 2024

Opened on May 20th. Filtered and vacuumed. No chemicals added.


Test Strip Results (May 23 rd)

ReadingValueStatusDesired StateCalculated Chemicals NeededWhat I AddedResult (Next Morning)
Hardness350ok200-300

Chlorineokok

-
Alkalinity80ok80-120 
-
Ph7.5ok7.5
-
CyA20low50


Salt600low3000



Test Report  (May 23 rd)

Image Added

OrderReadingValueStatusDesired StateCalculated Chemicals NeededWhat I AddedResult (Next Morning)

Hardness250OK200-300-

Chlorine1.5OK1-3 --
1Alkalinity50LOW80-120 3 kg Alka+1.5 kg Alka+

Ph7.2OK7.4-7.6-

3Stabilizer (CyA)0low30-60

Broadcast 4 kg of PROTECT CELL ULTRA 3 IN 1.

Slowly pour 700 g or 4 cups of STAB in the skimmer.

3 stab ultra pucks to skimmer
2Salt1920low300036 kg Salt20kg - 1 bag salt

Image Added


After a couple of weeks, notice the Ph was high.

ReadingValueStatusDesired StateCalculated Chemicals NeededWhat I AddedResult (Next Morning)
Ph8.0OK7.4-7.6480g Ph-300g Ph-


Chemicals

Info
titleAlways
  • Turn off cell for 24 hours after adding salt
  • Wait 48 hours after shock before getting sample for water test

...

Again using a 3/4" washer:



Pictures

Build

Yard Layout

Image Removed

Fence Design

Image Removed

Deck Design

Image Removed

Moving the Equipment 

Originally the pool equipment was installed in the garage. 

Image RemovedImage Removed

Later I decided to build out a part of the deck to have a space for the equipment.

Image RemovedImage Removed

Had to heat out the old PVC pipes to re-use the fittings

Image Removed

More pictures:

Image RemovedImage RemovedImage RemovedImage RemovedImage Removed

Permit

View file
nameScan05-21-2019-221814.pdf
height250
Image Removed View filenameFindlay Cres 19 BP1902990 Insp 20221121 Pool.pdfheight250


Suppliers

SupplierURL
Pool Supplies Canadahttps://www.poolsuppliescanada.ca/
Pool Store Canadahttps://www.poolstorecanada.ca/

...