MakeGSW
Model8G50NVH-ES-02
Capacity50 US Gal
Recup per/hour34.5 US Gal

Controller ( Intelli-vent )


Image Added


Image AddedImage AddedImage Added

Problem

High Temp Thermo Cut-Off

The controller was showing an error 11 code at startup indicating that the high temperature thermal cut-off had tripped. Turns out once this trips, you need to replace the unit.

Image Added

Image Added



Disassembling the Controller

I attempted to see if I could bypass the high temperature cut off but had no luck. Here are some pictures of the circuit board.



Image AddedImage Added

Temporary Fix

Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.

Image Added


Fix

I managed to buy a similar hot water tank with the same controller. Transfered the new controller to the old tank and all was well again. Perhaps I should have just installed the newer tank but didn't want to mess with all of the plumbing and the gas. Might do it at some point since the other tank is newer.

Image AddedImage Added

Donor Tank

SpecificationDetails
MakeGiant
ModelUG50-40LFPV1-N2U-DE
Capacity50 US Gal
Recup per/hour37.3 US Gal
User Manual


Image AddedImage AddedImage Added


Ignitor Problem

Image Added

Fix

Remove element and lightly sand the flame sense rod with emery cloth or steel wool.

https://www.youtube.com/watch?v=MuGY9nfcTZAImage Removed


References

ReferenceURL
SuperFlue Hot Water Tank Manual
Intellivent Trouble Shooting Guide
Service Manual