Zone Control System

SpecificationDetail
MakeRobertshaw
ModelSlimzone 2701-001/2701-006
DescriptionZone Control System
Installation Instructions






Thermostat


ConnectionDescription
Y1Cool
Y2
GFan
OB
RcPower
W1Heat
W2/AUX
C24V Common
*Humidifier
Rh

Heat and AC Hookup


Heat, AC and Humidifier Hookup







Humidifier

Modifications to the Humidifier

In order to have the humidifier work effectively with the nest thermostat, we should drive the solenoid only. We will not need the flow check switch or the on furnace mounted humidistat.


Remove wire from furnace mounted thermostat.


Remove the wire to the furnace mount thermistat at the solenoid controller.


Remove the cap to the controller and cut the wires for the flow check switch and marret the connections together. The other 2 wires go to the solenoid valve.



The end result should be resemble the following:



Wiring the Humidifier


In my zone control cabinet, I connected both *(HUM) wires from the thermostats to the HOT line of the humidifier.



References

ReferenceURL
Nest Pro Installer Guidehttp://support-assets.nest.com/images/pro-faq/Nest-Pro-Installer-Guide.pdf
How to Connect & Setup a Nest Thermostat to Function as a Humidistathttps://ohmefficient.com/connect-nest-thermostat-humidistat/