Equipment

Furnace

SpecificationDetails
MakeCarrier
Model59TP5A080
Filter Size16 x 25 x 4 3/8"
Details

Performance Series’ two stage high efficiency gas
furnace. This furnace has a Btu/h output of 78,000 in high fire and 50,000 in low fire
with an A.F.U.E. of 96.2%.

Air Conditioner

SpecificationDetails
MakeCarrier
Model24ABB330A003
Details

‘Comfort Series 13’ two and half ton air conditioning
condensing unit. This unit contains R-410A refrigerant.

Carrier CNPVP3617 - Three ton air conditioning cased coil

Dampers

SpecificationDetails
MakeRobert Shaw?
ModelDAOP1808E2
DescriptionRectangular Motorized Control Damper


Zone Control System

SpecificationDetail
MakeRobertshaw
ModelSlimzone 2701-001/2701-006
DescriptionZone Control System


Zone Control System

User Manual


Wiring




Dampers

Two wire dampers are powered closed and spring return open. Three wire dampers are powered closed and powered open.

Our dampers are two wire dampers and should be connected to PC and X (Common).


Specifications

SpecificationDetails
ModelDAOP1808E2
DescriptionRectangular Motorized Control Damper


LED Status Indication











Thermostat

ConnectionDescription
Y1Cool
Y2
GFan
OB
RcPower
W1Heat
W2/AUX
C24V Common
*Humidifier
Rh

Heat and AC Hookup


Heat, AC and Humidifier Hookup







Humidifier

Modifications to the Humidifier

In order to have the humidifier work effectively with the nest thermostat, we should drive the solenoid only. We will not need the flow check switch or the on furnace mounted humidistat.


Remove wire from furnace mounted thermostat.


Remove the wire to the furnace mount thermistat at the solenoid controller.


Remove the cap to the controller and cut the wires for the flow check switch and marret the connections together. The other 2 wires go to the solenoid valve.



The end result should be resemble the following:



Wiring the Humidifier


In my zone control cabinet, I connected both *(HUM) wires from the thermostats to the HOT line of the humidifier.



Installers

HOWARD BOYLE
Heating and Air Conditioning
1726 Bank St. Unit ‘C’ Ottawa ON, K1V 7Y6
Tel. (613) 829-4000 Fax. (613) 829-3066

References

ReferenceURL
Nest Pro Installer Guidehttp://support-assets.nest.com/images/pro-faq/Nest-Pro-Installer-Guide.pdf
How to Connect & Setup a Nest Thermostat to Function as a Humidistathttps://ohmefficient.com/connect-nest-thermostat-humidistat/












  • No labels