Honeywell HE280C2010/U Higher Capacity Whole House Bypass Humidifier

Image Modified

Controller Images



Schematic


Here is the schematic that I put together based on some testing.

...

  • D2 is a zener diode which acts as a voltage regulator for the 555 chip.


555 Timer Reference Diagram


Image Added




The Fix


Since the solenoid was no longer activating, it seemed like a replacing it was in order. The replacement solenoid that I purchased was rated 24 VDC but didn't activate when connected.


I opted to bypass the 555 timer circuitry by pin 4 of the jumper (JP3) to ground.

Image Added