Overview

Honeywell HE280C2010/U Higher Capacity Whole House Bypass Humidifier

Controller Images



Schematic


Here is the schematic that I put together based on some testing.

You would think that the GND pin on the 555 would go to ground via a pullup and that would be that.



Other thoughts:

  • D2 is a zener diode which acts as a voltage regulator for the 555 chip.


555 Timer Reference Diagram





The Fix


Since the solenoid was no longer activating, it seemed like a replacing it was in order. The replacement solenoid that I purchased was rated 24 VDC but didn't activate when connected.


I opted to bypass the 555 timer circuitry by pin 4 of the jumper (JP3) to ground.



New Parts

  • Solenoid valve: Baomain 1/4 Inch Brass Electric Solenoid Valve for Air Water Valve N/C (Normally Closed) DC 24V
  • Generic Pneumatic Push in Quick Touch to Connect Fitting 1/4" OD Tube x 1/4" Male NPT 90 Deg Swivel Elbow Coupler