SIN9020S Voltage Meter
Overview
The SIN9020S voltage meter is able to measure:
- voltage
- current
- charge and discharge capacity
- time
- power
Protection Features
- over voltage protection
- under voltage protection
- over current protection
- over-charging capacity protection
Technical Specs
Project | Parameters | ||
Voltage measuring range | Self-powered voltage measurement range | 10V~90V | |
External power measurement range | 0~90V | ||
Current input \ output current measurement range | 0~20A | ||
Display method | Color liquid crystal display | ||
Display Resolution | Voltage | 0.01V | |
Current | 0.01A | ||
Capacity | 0.01AH | ||
Time | 1min | ||
Accuracy | Voltage | 1% + 2 words | |
Current | 2% + 5 words | ||
Measurement rate | 5 times / sec | ||
OFT (out protection) | 0.01H~99.9H | ||
Dimensions (length × width × height) | 79×43×52(mm) | ||
Mounting hole opening (mm) | 76.5*39.2(mm) |
Wiring
From factory, Vext is connected to VCC.
To power the meter from an independent source, you will need to unsolder a jumper inside the meter. Once done, you can power the meter from an independent source.
Useful Functionality
LOP
LOP is under voltage protection. When the output voltage drops below the setting, the meter will automatically cut off the output, and the output indicator will change from green to gray.
References
Reference | URL |
---|---|
Manual for SIN9020S Voltage Meter |