SIN9020S Voltage Meter

Overview

The SIN9020S voltage meter is able to measure:

  • voltage
  • current
  • charge and discharge capacity
  • time
  • power

Protection Features

  • over voltage protection
  • under voltage protection
  • over current protection
  • over-charging capacity protection 


Technical Specs

Project

Parameters

Voltage measuring range

Self-powered voltage measurement  range

10V~90V

External power measurement range

0~90V

 Current input \ output current measurement range

          0~20A

Display method

  Color liquid crystal display

Display Resolution

Voltage

0.01V

Current

0.01A

Capacity

0.01AH

Time

1min

Accuracy

Voltage

 1% + 2 words

Current

 2% + 5 words

             Measurement rate

 5 times / sec


OFT (out protection)

0.01H~99.9H

Dimensions (length × width × height)

79×43×52(mm)

Mounting hole opening (mm)

76.5*39.2(mm)

Wiring

From factory, Vext is connected to VCC. 


To power the meter from an independent source, you will need to unsolder a jumper inside the meter. Once done, you can power the meter from an independent source.


Useful Functionality

LOP

LOP is under voltage protection. When the output voltage drops below the setting, the meter will automatically cut off the output, and the output indicator will change from green to gray.