You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 9 Next »

Overview



Controller ( Intelli-vent )



Problem

The controller was showing an error 11 code at startup indicating that the high temperature thermal cut-off had tripped. Turns out once this trips, you need to replace the unit.



Disassembling the Controller

I attempted to see if I could bypass the high temperature cut off but had no luck. Here are some pictures of the circuit board.



Temporary Fix

Picked up 10L electric water heater and connected it to the hot and cold line near the shower. Allows for a quick shower when desperate.

Fix

I managed to buy a similar hot water tank with the same controller. Transfered the new controller to the old tank and all was well again. Perhaps I should have just installed the newer tank but didn't want to mess with all of the plumbing and the gas. Might do it at some point since the other tank is newer.

References

ReferenceURL
Intellivent Trouble Shooting Guide
Service Manual



  • No labels